Removal of malpositioned implants

Mansour Mirzaie

Private clinic in Germany

E-mail : bhuvaneswari.bibleraaj@uhsm.nhs.uk

DOI: 10.15761/DOMR.1000346

Article
Article Info
Author Info
Figures & Data

Abstract

Dental implants are nowadays one the best and most popular substitute alternatives to replace extracted teeth. The restoration of teeth with implants and subsequent supraconstruction with removable or fixed prosthetics is a technique sensitive procedure.

Several factors may affect the final outcome of the treatment such as:

1-quality and quantity of implant surrounding bone

2- correct angulation of implants

3- soft tissue biotype

4- depth of inserted implant

5- fabrication of the prosthetic part

Although most recent technology like cbct, surgical guides and simulation computer software enables the technicians more predictable placement of implants, we face pretty often implants, which must be removed.

Improper angulation of inserted implants may lead to:

A- Insufficient bone support around the implant

B- insufficient soft tissue stability and subsequently anticipated Periimplantitis after loading.

C- undesired occlusal overloading

D- unsatisfying aesthetic outcomes

E- Lack of proper occlusal function

Therefore, is the removal and replacing the implant in such cases the best solution.

Conventional methods to remove implants, which are fully integrated with the surrounding bone such as utilizing trephine burs, high Speed burs, forceps, piezo tips and counter-torque ratchet lead to:

A- enormously bone loss around the implant

B- jeopardizing critical anatomical structures like vessels and nerves

C- making a simultaneous replacement impossible

In a method developing by myself are all above mentioned factors excluded.

Materials and methods

Monopolar electrosurgery device

A patient with 8 inserted implants in lower jaw was referred to me for making ginvivoplsty. The patient forgot to stop ASA- medication 4 days pre-op so I made the gingivoplaty via electrosurgery device.

The device was set at cutting mode with an intensity of 6-7. There were small corrections to take on all implants besides the one substituting tooth 34. This implant got disintegrated after seven days, so I could unscrew it with a ratchet without utilizing any force.

After removing the implant the socket was checked with a perio-probe and a bone curette, whereby no signs of necrosis were to observe. In the same session another implant was inserted in the same socket with a 0,4 mm thicker diameter, which got integrated completely after three months.

47 implants were removed within one year and half with the same method. In all cases was a simultaneous replacement possible.

Conclusion

Utilizing electrosurgery sets in cutting mode with an intensity of 6-7 enables the practitioner to remove an implant after one week without any damage to surrounding tissues and simultaneous replacement of it.

Most important issue by using this technique is to jab the implant neck circumferential. In almost all cases were 5-6 touches were sufficient to loosen the osseointegrated implant.

Editorial Information

Founding Editor-in-Chief

Shigeru Watanabe
Meikai University Japan

Editor-in-Chief

Hao Yu
Fujian Medical University
Vagner Rodrigues
Federal University of Minas Gerais

Article Type

Short Communication Article

Publication history

Received: May 08, 2020
Accepted: May 20, 2020
Published: May 22, 2020

Copyright

©2020 Mirzaie M. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Citation

Mirzaie M (2020) Removal of malpositioned implants. Dent Oral Maxillofac Res 6: DOI: 10.15761/DOMR.1000346

Corresponding author

Dr. Mansour Mirzaie DDS. M.Sc (Periodontics)

Private clinic in Germany

E-mail : bhuvaneswari.bibleraaj@uhsm.nhs.uk

No data.